DS880F4 105
CS4207
Response Format:
Bits [31:0] are sticky and will not be reset by a Link Reset or a Codec Reset:
6.11.13 Mic In 1/Line In 2 Configuration Default
The Configuration Default register is used by software as an aid in determining the configuration of jacks
and devices attached to the codec. At the time the codec is first powered on, this register is internally load-
ed with default values indicating the typical system use of this particular pin/jack. After this initial loading,
it is completely codec opaque, and its state, including any software writes into the register, must be pre-
served across reset events such as Link Reset or Codec Reset (the Function Reset Verb). Its state need
not be preserved across power level changes.
Get Parameter Command Format:
Set Parameter Command Format:
Response Format:
Bits Type Default Description
31:30 Read/Write 00b
Port Connectivity (PCON): The port complex is
connected to a jack.
29:24 Read/Write 000001b
Location (LOC): This field indicates the physical
location of the jack or device to which the pin
complex is connected. Set to External | Rear.
23:20 Read/Write 8h
Default Device (DD): Indicates the intended use
of the connection is for Line In.
19:16 Read/Write 1h
Connection Type (CTYP): Indicates the type of
physical connection is 1/8” jack.
15:12 Read/Write 3h
Color (COL): This field indicates the color of the
physical jack for use by software. The color
selected is Blue.
11:8 Read/Write 0h
Miscellaneous (MISC): No PDC override.
7:4 Read/Write 5h
Default Association (DA): This field is used by
software to group Pin Complex (and therefore
jacks) together into functional blocks to support
multichannel operation. All jacks with the same
association number may be assumed to be
grouped together. A value of all ‘0’s is reserved.
A value of all ‘1’s in this field indicates that the
Association has the lowest priority.
3:0 Read/Write 1h
Sequence (SEQ): This field indicates the order
of the jacks in the association group.
Bits [31:28] Bits [27:20] Bits [19:8] Bits [7:0]
CAd = X Node ID = 0Dh Verb ID = F1Ch Payload = 00h
Bits [31:28] Bits [27:20] Bits [19:8] Bits [7:0]
CAd = X Node ID = 0Dh Verb ID = 71Ch Payload = xxh (Config bits [7:0])
CAd = X Node ID = 0Dh Verb ID = 71Dh Payload = xxh (Config bits [15:8])
CAd = X Node ID = 0Dh Verb ID = 71Eh Payload = xxh (Config bits [23:16])
CAd = X Node ID = 0Dh Verb ID = 71Fh Payload = xxh (Config bits [31:24])