Cirrus-logic CS2300-OTP User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
CS2300-OTP
DS844F2 7
AC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; T
A
= -10°C to +70°C (Commercial Grade);
T
A
= -40°C to +85°C (Automotive Grade); C
L
=15pF.
Notes: 5. f
CLK_OUT
= 24.576 MHz; Sample size = 10,000 points; AuxOutSrc[1:0] =11.
6. In accordance with AES-12id-2006 section 3.4.2. Measurements are Time Interval Error taken with 3rd
order 100 Hz to 40 kHz bandpass filter.
7. In accordance with AES-12id-2006 section 3.4.1. Measurements are Time Interval Error taken with 3rd
order 100 Hz Highpass filter.
8. 1 UI (unit interval) corresponds to t
CLK_IN
or 1/f
CLK_IN
.
Parameters Symbol Conditions Min Typ Max Units
Clock Input Frequency f
CLK_IN
50 Hz - 30 MHz
Clock Input Pulse Width pw
CLK_IN
f
CLK_IN
< 175 kHz
f
CLK_IN
> 175 kHz
140
10
-
-
-
-
ns
ns
PLL Clock Output Frequency f
CLK_OUT
6-75MHz
PLL Clock Output Duty Cycle t
OD
Measured at VD/2 45 50 55 %
Clock Output Rise Time t
OR
20% to 80% of VD - 1.7 3.0 ns
Clock Output Fall Time t
OF
80% to 20% of VD - 1.7 3.0 ns
Period Jitter t
JIT
(Note 5) - 35 - ps rms
Base Band Jitter (100 Hz to 40 kHz) (Notes 5, 6) - 50 - ps rms
Wide Band JItter (100 Hz Corner) (Notes 5, 7) - 150 - ps rms
PLL Lock Time - CLK_IN (Note 8)t
LC
f
CLK_IN
< 200 kHz
f
CLK_IN
> 200 kHz
-
-
100
1
200
3
UI
ms