Function:
The level of ADCX can be adjusted in 1.0 dB increments as dictated by the ADCx Soft and Zero Cross bits
(SOFTx & ZCROSSx) from 0 to -96 dB. Levels are decoded in two’s complement, as shown in the table
above.
Note: When the ALC is enabled, the Attenuator and PGA volume is automatically controlled and should
not be adjusted manually.
6.11 ADCx Mixer Volume Control: ADCA (Address 0Eh) & ADCB (Address 0Fh)
Note: The SPE_ENABLE bit in reg09h must be set to 1 to enable function control in this register.
ADCX Mixer Channel Mute (MUTE_ADCMIXX)
Default: 1
0 - Disabled
1 - Enabled
Function:
The ADC channel X input to the output mixer will mute when enabled. The muting function is affected by
the SPEX Soft and Zero Cross bits (SPEX_SZC[1:0]).
ADCX Mixer Volume Control (ADCMIXX_VOL[6:0])
Default = 000 0000
Function:
The level of the ADCX input to the output mixer can be adjusted in 0.5 dB increments as dictated by the
SPEX Soft and Zero Cross bits (SPE_SZC[1:0]) from +12 to -51.5 dB. Levels are decoded as shown in the
table above.
6.12 Channel Mixer (Address 18h)
Note: The SPE_ENABLE bits in reg09h must be set to 1 to enable function control in this register.
Channel Mixer (ADCx[1:0])
Default: 00
7 6543210
MUTE_ADCMIXx ADCMIXx_VOL6 ADCMIXx_VOL5 ADCMIXx_VOL4 ADCMIXx_VOL3 ADCMIXx_VOL2 ADCMIXx_VOL1 ADCMIXx_VOL0
Binary Code Volume Setting
001 1000 +12.0 dB
··· ···
000 0000 0 dB
111 1111 -0.5 dB
111 1110 -1.0 dB
··· ···
001 1001 -51.5 dB
76543210
Reserved Reserved Reserved Reserved ADCA1 ADCA0 ADCB1 ADCB0
ADCA[1:0] SDOUT ADCB[1:0] SDOUT
00 L 00 R