Cirrus-logic CapturePlus II User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
CapturePlus II
30 DS789UM2
A.1.4 Baseline Noise & Distortion Test - Histogram Analysis
Connect the evaluation board’s analog input(s) to circuit ground.
Select the Histogram window by clicking on the Histogram tab at the top of the screen.
Click on the Acquire button. Within the Acquire sub-panel, set Select Number of Samples to Capture to
524288. Set the Channel(s) to Capture to the desired channel(s).
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 41 42

Comments to this Manuals

No comments