Management Interface Variable Reference
Name
conductorGaps
Description
These timing specifications are applicable only to repeater networks and therfore do not apply to
most CobraNet applications. This variable is changed on the active conductor in order to reduce the
probability of collisions. In most cases the default value works well. Useful values other than the
default are dependant on the specific network topology used.
Channel Gap in LS byte - Larger channel gaps allow greater network diameter.
Packet Gap in MS byte - Larger packet gaps increase resilience to unregulated traffic.
Host Address
0x10003
SNMP Object ID
1.3.6.1.4.1.2680.1.1.4.3
Type
Integer16
Attributes
Read/write - Persistent
Default Value
0x0306
Implemented Version
2.2.0
Name
conductorStatus
Description
Conductor status:
0 - This interface is not the conductor
1 - This interface is the conductor
Host Address
0x11000
SNMP Object ID
1.3.6.1.4.1.2680.1.1.4.4
Type
Integer
Attributes
Read-only
Implemented Version
2.1.0